Sun StorEdge Network 2 Gb FC Series Switches
Timeout Values
P
AGE 272 QLOGIC SWITCH INTEROPERABILITY GUIDE
VERSION 1.0, MARCH 2003
Timeout Values
As per FC-SW-2 Fibre Channel standards, set all switches to the following timeout values (TOV)
in order to successfully establish an E-port connection:
R_A_TOV = 10 seconds
E_D_TOV = 2 seconds
This section provides the steps to change these values.
Sun StorEdge SANbox Manager GUI
ATTENTION!!
The following steps take the switch offline; therefore, do not perform them on a
switch being managed in-band.
1. Start the SANbox Manager application. The SANbox ManagerFaceplate dialog box
displays.
2. From the SANbox ManagerFaceplate dialog box Switch menu, select Switch Properties.
For the Sun StorEdge Network 2 Gb FC Switch-8 and Sun StorEdge Network 2 Gb FC
Switch-16, the following displays: