Q-Logic SN0135524-00 Uživatelský manuál Strana 142

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 320
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 141
IBM eServer BladeCenter Fibre Channel Switch Module
Timeout Values
P
AGE 130 QLOGIC SWITCH INTEROPERABILITY GUIDE
VERSION 1.0, MARCH 2003
Timeout Values
As per FC-SW-2 Fibre Channel standards, set all switches to the following timeout values (TOV)
in order to successfully establish an E-port connection:
R_A_TOV = 10 seconds
E_D_TOV = 2 seconds
This section provides the steps to change these values.
IBM eServer BladeCenter SAN Utility
ATTENTION!!
The following steps take the switch offline; therefore, do not perform them on a
switch being managed in-band.
1. Start the IBM eServer BladeCenter SAN Utility. The IBM BladeCenter SAN
UtilityFaceplate dialog box displays.
2. From the IBM BladeCenter SAN UtilityFaceplate dialog box Switch menu, select Switch
Properties.
Zobrazit stránku 141