McDATA Intrepid 6000 Series Directors
Timeout Values
QL
OGIC SWITCH INTEROPERABILITY GUIDE PAGE 231
V
ERSION 1.0, MARCH 2003
Timeout Values
As per FC-SW-2 Fibre Channel standards, set all switches to the following timeout values (TOV)
in order to successfully establish an E-port connection:
R_A_TOV = 10 seconds
E_D_TOV = 2 seconds
This section provides the steps to change these values.
McDATA SANpilot Web Management
1. Start McDATA SANpilot Web Management. The Main Director View dialog box displays.
2. On the navigation panel, select Configure. The Configure dialog box displays. Select the
Director tab, then select the Fabric Parameters tab. Verify that R_A_TOV is set to 100 and
E_D_TOV is set to 20. If the settings are not correct, proceed to step 3. If the settings are
correct, no changes need to be made; proceed to the next appropriate section.